U-value

The U-value collects a construction's total thermal resistance into a single number: the heat loss per square meter and degree of temperature difference. A low U-value means good insulation. Building codes often set requirements for the maximum U-value of walls, roofs and windows.

U=1RtotAU = \dfrac{1}{R_{tot}A}U-value from total resistance
Q˙=UAΔT\dot Q = UA\Delta Theat loss from the U-value

Symbols

UUU-valueW/(m²·K)
AAaream²

Example

A wall has RtotA=3.5R_{tot}A = 3.5 m²K/W. U=1/3.5≈0.286U = 1/3.5 \approx 0.286 W/(m²·K). With A=15A = 15 m² and ΔT=30\Delta T = 30 K: Q˙≈128.6\dot Q \approx 128.6 W.

The lower the U-value, the better the insulation – the opposite of the thermal conductivity kk, where a higher value means worse insulation.
Practise conduction for free →

← Cylindrical thermal resistance · Newton's law of cooling →

Part of Heat Transfer: Conduction.