Wheatstone Bridge

A Wheatstone bridge consists of four resistors connected in a diamond shape, and is used to measure very small resistance changes, for example from a strain gauge. When the bridge is balanced, the output voltage is zero; a small change ΔR\Delta R in one arm gives a small, measurable differential voltage that can be amplified.

ΔR=GF⋅ε⋅R\Delta R = GF\cdot\varepsilon\cdot Rresistance change from strain in a strain gauge

Symbols

GFGFgauge factor (the strain gauge's sensitivity)
ε\varepsilonstrain
RRthe resistor's nominal valueΩ\Omega
ΔR\Delta Rresistance changeΩ\Omega

Example

GF=2GF=2, ε=0.001\varepsilon=0.001, R=120R=120 Ω:

ΔR=2⋅0.001⋅120=0.24\Delta R=2\cdot0.001\cdot120=0.24 Ω.

When balanced the output voltage is zero – even a small ΔR\Delta R then gives a clear reading.